| Sign In | Join Free | My udpf.com | 
              
  | 
      
Brand Name : AI
Model Number : 4530F
Certification : ISO
Place of Origin : China
MOQ : 1 set Atomic Absorption Spectroscopy
Price : Negotiable
Payment Terms : L/C, T/T, Western Union
Supply Ability : 20 sets per month
Delivery Time : Atomic Absorption Spectroscopy packed in 20 days
Packaging Details : Plywood case
Test method : Atomic Absorption Spectrometry AAS
Wavelength Range : 190 ~ 900nm
Wavelength Accuracy : ±0.15nm
Lamp Turrets : 8 PCS
Spectrum Bandwidth : 0.1nm, 0.2nm, 0.4nm, 1.0nm And 2.0nm
The highest temperature : 3000℃
The largest temperature rising speed : ≥2000℃/S
Dimension of main unit : 550mm×450mm×300mm
Features: 
 This AAS machine is complete automatic controlling system;
 The AA spectrophotometer can be worked with advanced graphite furnace temperature controlling technology;
 Safe, reliable and convenient flame system;
 Multi-functional software workstation;
 This flame system atomic absorption spectrophotometer is ompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
 Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
 Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
 Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
 Fully automated wavelength scanning and peak searching;
 Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
 Deuterium lamp and self-absorption background regulation;
 Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
 Measuring method of AAS machine: flame absorption method and emission method;
 Result printing: parameter printing, data result printing and diagram printing;
Instrument Configuration:
Atomic Absorption Spectrophotometer 1pc
 Air compressor without noise 1pc
 PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
 A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)
Specifications:
| Wavelength range | 190 ~ 900nm | 
| Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm | 
| Accuracy of the wavelength | ±0.15nm | 
| Receptivity of the wavelength | ≤0.04nm | 
| Base line stability | ≤0.002A/30min (Cu) | 
| Characteristic viscosity | 0.02μg/ml/1% (Cu) | 
| Checking limit | 0.004μg/ml (Cu) | 
| Preciseness | 0.5% | 
| Grating | 1800 lines/mm | 
| Inflamer | All-metal titanium burner | 
| Atomizer | Effective glass atomizer | 
| Lamp stand | Eight lamps | 
| D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method | 
| Size and weight | 700mm×550mm×450mm 75Kg | 
| Power source | 220V±22V AC | 
 Flame System:
| Acetylene air burner | 100mm | 
| Nitrous oxide acetylene flame head | 50mm | 
| Ignition dynamic baseline drift | ≤0.006A/30min | 
| (Cu) Characteristic viscosity | ≤0.025μg/ml/1% | 
| Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) | 
| Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner | 
 Graphite Furnace:
| The highest temperature | 3000℃ | 
| The largest temperature rising speed | ≥2000℃/S | 
| Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g | 
| Accuracy | Cu≤3% Cd≤3% | 
| Size and weight | 550mm×450mm×300mm 65Kg | 
| Safety system | Over current protection | 
| Protection | Low air pressure alarm, low cooling water flow alarm | 
| Power source and power | 220V±22V AC 7000W | 
Spares package of 4530F Automatic Atomic Absorption Spectroscopy AAS Machine


| 
                                             | 
                
                        Automatic Atomic Absorption Spectroscopy AAS Machine for Elements Detection Images |