Sign In | Join Free | My udpf.com
China Advanced Instruments Co.,Limited logo
Advanced Instruments Co.,Limited
Advanced Instruments Co.,Limited To Be Advanced in Quality and Service!
Verified Supplier

6 Years

Home > Transformer Test Equipment >

Transformer No Load Loss and Load Loss Measurement Equipment

Advanced Instruments Co.,Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Transformer No Load Loss and Load Loss Measurement Equipment

  • 1
  • 2
  • 3

Brand Name : AI

Model Number : KFZ

Certification : ISO9001

Place of Origin : China

MOQ : 1 set Transformer No Load and Load Measurement Equipment

Price : Negotiable

Payment Terms : Western Union, T/T, L/C

Supply Ability : 100 sets each month

Delivery Time : 15 days

Packaging Details : Transformer No Load and Load Measurement Equipment Packed in veneer case

Function : Transformer capacity, no-load current, no-load loss, short circuit voltage, short circuit (load) loss

Capacity test range-10kV Dry type transformer : 30kVA~3150kVA

Capacity test range-10kV Oil immersed transformer : 30kVA~3150kVA

Capacity test range-35kV Oil immersed transformer : 50kVA~31500kVA

Capacity test range-20kV Dry type transformer : 50kVA~2500kVA

Capacity test range-35kV Dry type transformer : 50kVA~2000kVA

Data storage : 500 groups

Dimension : 40cm*30cm*22cm

Weight : 8kg

Warranty : 1 Year

Contact Now

Introduction:

Transformer No Load and Load Measurement Equipment is designed for transformer capacity, load loss and no load loss testing, it can measure following parameters of transformer: capacity, transformer type, no-load current, no-load loss, short circuit (load) loss and impedance voltage.

Transformer No Load and Load Measurement Equipment is reliable, accurate, simple for wiring and operation.

Features:

  • Measurement range of voltage, current and capacity is wide, and measurement range can convert automatically. For example, the instrument can complete load test under full current of distribution transformer below 1000kVA. The load test of distribution transformers below 3150kV can be completed under 1/3 of the rated current (under 1/3 rated current, the instrument can be converted to the load loss parameter under the rated current).

  • When testing load and no load loss of three phase transformer, it can automatically determine whether the wiring is correct or not, and display vector of three phase voltage and current.

  • All test results can be automatically corrected by the Transformer No Load and Load Measurement Equipment.

  • LCD 20 * 240 large screen.

  • Users can preset 40 sets sample parameters, and these parameters can be deleted or added at any time.

  • With real-time electronic clock, which can automatically record test date and time.

  • 500 sets test data can be stored in the tester, meanwhile, users can connect the tester with computer to upload the data.

  • Transformer No Load and Load Measurement Equipment adopts built-in printer, users can print test result immediately after test.

  • Allows external current transformers or voltage transformers to extend measurement range, so it can test any kinds of transformers.

Specifications:

1 Test Parameters

Transformer capacity, no-load current, no-load loss,

short circuit voltage, short circuit (load) loss

2 Working power Input voltage 185Vac~250Vac
Allowable input voltage 85Vac~264Vac
Frequency 50/60Hz
Allowable frequency 45Hz~65Hz
Input power 40VA
3 AC voltage Range 10~650V
Resolution 0.001V
Accuracy 0.2%±0.001V
4 AC Current Range 0.5~60A
Resolution 0.001A
Accuracy 0.2%±0.001A
5 Frequency Range 45Hz~65Hz
Resolution 0.001Hz
Accuracy 0.2%±0.001Hz
6 Power Range 0~39kW
Resolution 0.001kW
Accuracy

<±0.5%(CosΦ>0.1) ±1.0%(0.02<CosΦ<0.1)

7 Capacity test range 10kV Dry type transformer 30kVA~3150kVA
10kV Oil immersed transformer 30kVA~3150kVA
35kV Oil immersed transformer 50kVA~31500kVA
20kV Dry type transformer 50kVA~2500kVA
35kV Dry type transformer 50kVA~2000kVA
8 Environment Operating temperature -10℃~+50℃
Storage temperature -25℃~+70℃
Relative humidity 5%~95%
9 Dimension 40cm*30cm*22cm
10 Weight 8kg (Excluding accessories)

Transformer No Load Loss and Load Loss Measurement Equipment


Product Tags:

Transformer No Load Measurement

      

No Load Measurement Equipment

      

Transformer Load Measurement Equipment

      
Best Transformer No Load Loss and Load Loss Measurement Equipment wholesale

Transformer No Load Loss and Load Loss Measurement Equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Advanced Instruments Co.,Limited
*Subject:
*Message:
Characters Remaining: (0/3000)